Industrial Smart Control Split Air Conditioning Units Low Noise 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: EKDB 125A(R) - EKDB 200A(R)

EKDB 125A(R) - EKDB 200A(R)   high static pressure duct type air conditioning unit
 
 

EKDB 125A(R) - EKDB 200A(R)   high static pressure duct type air conditioning unit

 

 

Specifications:

 

Unit model Indoor unit EKDB
125A
EKDB
125AR
EKDB
150A
EKDB
150AR
EKDB
200A
EKDB
200AR
Outdoor unit EKAA
125AB
EKAA
125ARB
EKAA
150AB
EKAA
150ARB
2xEKAA
100AB
2xEKAA
100ARB
Nominal cooling capacity W 30000 30000 40000 40000 50000 50000
Nominal heating capacity W -- 32500 -- 46000 -- 56000
Indoor unit Air flow m3/h 6500 7800 10800
External static pressure Pa 150 150 150
Fan drive mode V-belt transmission
Width x depth x height mm 1719x965x736
Weight kg 188 188 193
Outdoor unit Compressor model Fully hermetic volute
Width x depth x height mm 990x840x1840 1290x840x1840 2x990x840x1840
Weight kg 270 285 285 300 2x265 2x280
Power supply 380V/3N~/50Hz
Rated input power
of integrated unit
Cooling W 12100 12245 16130 17470 20410 20165
Heating W -- 10000 -- 14700 -- 20300
Rated current of integrated unit Cooling A 22 22 30 30 37 36
Heating A -- 20.5 -- 29 -- 39
Refrigerant Type R22
Connection pipe Connect mode Soldering
External diameter of liquid tube mm 15.88 15.88 2x15.88
External diameter of air tube mm 28.6 34.9 2x28.6
Condensed water drainage pipe R1
External electric heater box Model ACDB-EH6, ACDB-EH8, ACDB-EH10, ACDB-EH12.5, ACDB-EH15, ACDB-EH20, ACDB-EH25, ACDB-EH30, ACDB-EH38, ACDB-EH45, ACDB-EH55
Description You can select an external electric heater box according
to the required heating capacity. For specifications of external electric heater boxes, see P22.

 

Note:
The rated cooling capacity is measured in the following condition: The indoor air dry bulb reads 27°C, the wet bulb reads 19°C, and the
outdoor dry bulb reads 35°C. The condition for the rated heating capacity is as follows: The indoor air dry bulb reads 20°C, the outdoor dry
bulb reads 7°C, and the wet bulb reads 6°C. The cooling capacity and heating capacity change according to the conditions. During model
selection, you need to select a proper model based on local climatic conditions.
External static pressure indicates the static pressure under the nominal air flow. The static pressure may change depending on customer
requirements. For the specific value, see the reading on the nameplate.
The unit input power and current are based on the standard external static pressure. If the customer requires a different external static
pressure, check the nameplate on the unit for the power and current values.
The specifications may suffer change due to product update. The readings on the nameplate of the unit prevail.
The preceding data is based on the condition that the connection pipe between indoor and outdoor units is 7.5m.
For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit.
No refrigerant is filled into any unit upon factory delivery

 

Description:

 

1, Outstanding fans, motors and other components specially designed for air conditioners ensure that the unit operates smoothly.

2, Brand-new dustproof and rustproof painting makes sure that the outdoor unit looks new after many years of operation.

3, The outdoor unit adopts modular design and stepped startup, efficiently reducing shock on the grid.

4, Multiple levels of cooling are provided, allowing differential energy regulation under different load conditions and reducing the operating cost.

5, The compressors support even wear, prolonging the lifecycle

6, Featuring a high static pressure design, the indoor unit can supply conditioned air over a long distance, enabling customers to select the installation site as required. To service any component of the unit, you only need to remove several screws on either side of the unit.

7, The connection pipe between indoor and outdoor units reaches up to 50 m, and the height difference can reach 20 m.

8, The outdoor unit adopts top air supply, allowing combined installation of multiple outdoor units for pleasant appearance.

9, The indoor unit features an efficient and low-noise centrifugal fan as well as sound-

bigPhoto
 Mr. Rocky

Tel: 86-769-83660888
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

EuroKlimat Air Conditioning Refrigeration Company [China (Mainland)]


Business Type:Manufacturer
City: Dongguan
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (197)